| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The ReadFile endpoint of the firmware for Mennekes Smart / Premium Chargingpoints can be abused to read arbitrary files from the underlying OS. |
|
CWE-552: Files or Directories Accessible to External Parties vulnerability exists that could allow
unauthenticated files and logs exfiltration and download of files when an attacker modifies the
URL to download to a different location.
|
| The CGI script <redacted>.sh can be used to download any file on the filesystem.
This issue affects Iocharger firmware for AC model chargers beforeversion 24120701.
Likelihood: High, but credentials required.
Impact: Critical – The script can be used to download any file on the filesystem, including sensitive files such as /etc/shadow, the CGI script source code or binaries and configuration files.
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:P/AU:Y
CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The confidentiality of all files of the devicd can be compromised (VC:H/VI:N/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, this attack in isolation does not have a safety impact. The attack can be automated (AU:Y). |
| CWE-552: Files or Directories Accessible to External Parties vulnerability over https exists that could leak
information and potential privilege escalation following man in the middle attack. |
| Three Bitnami Helm charts mount Kubernetes Secrets under a predictable path (/opt/bitnami/*/secrets) that is located within the web server document root.
In affected versions, this can lead to unauthenticated access to sensitive credentials via HTTP/S. A remote attacker could retrieve these secrets by accessing specific URLs if the application is exposed externally. The issue affects deployments using the default value of usePasswordFiles=true, which mounts secrets as files into the container filesystem. |
| FutureNet MA and IP-K series provided by Century Systems Co., Ltd. put the firmware version and the garbage collection information on the internal web page. With some crafted HTTP request, they can be accessed without authentication. |
| dstack is a software development kit (SDK) to simplify the deployment of arbitrary containerized apps into trusted execution environments. In versions of dstack prior to 0.5.4, a malicious host may provide a crafted LUKS2 data volume to a dstack CVM for use as the `/data` mount. The guest will open the volume and write secret data using a volume key known to the attacker, causing disclosure of Wireguard keys and other secret information. The attacker can also pre-load data on the device, which could potentially compromise guest execution. LUKS2 volume metadata is not authenticated and supports null key-encryption algorithms, allowing an attacker to create a volume such that the volume opens (cryptsetup open) without error using any passphrase or token, records all writes in plaintext (or ciphertext with an attacker-known key), and/or contains arbitrary data chosen by the attacker. Version 0.5.4 of dstack contains a patch that addresses LUKS headers. |
| OA EKP v16 was discovered to contain an arbitrary download vulnerability via the component /ui/sys_ui_extend/sysUiExtend.do. This vulnerability allows attackers to obtain the password of the background administrator and further obtain database permissions. |
| Longjing Technology BEMS API versions up to and including 1.21 contains an unauthenticated arbitrary file download vulnerability in the 'downloads' endpoint. The 'fileName' parameter is not properly sanitized, allowing attackers to craft traversal sequences and access sensitive files outside the intended directory. |
| An attacker could obtain firmware files and reverse engineer their
intended use leading to loss of confidentiality and integrity of the
hardware devices enabled by the Qardio iOS and Android applications. |
| Local File Inclusion vulnerability in Ready's attachment upload panel allows low privileged user to provide link to a local file using the file:// protocol thus allowing the attacker to read content of the file. This vulnerability can be use to read content of system files. |
| Improper access control vulnerability in Apaczka plugin for PrestaShop allows information gathering from saved templates without authentication.This issue affects Apaczka plugin for PrestaShop from v1 through v4. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.80), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.80), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.80), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ81 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SK82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.80), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.80), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7ST85 (CP300) (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V9.80), SIPROTEC 5 7SX82 (CP150) (All versions < V9.80), SIPROTEC 5 7SX85 (CP300) (All versions < V9.80), SIPROTEC 5 7SY82 (CP150) (All versions < V9.80), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.80), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VU85 (CP300) (All versions < V9.80), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.80). Affected devices do not properly limit the path accessible via their webserver. This could allow an authenticated remote attacker to read arbitrary files from the filesystem of affected devices. |
| Potential privilege escalation vulnerability in Revenera InstallShield versions 2022 R2 and 2021 R2 due to adding InstallScript custom action to a Basic MSI or InstallScript MSI project extracting few binaries to a predefined writable folder during installation time. The standard user account has write access to these files and folders, hence replacing them during installation time can lead to a DLL hijacking vulnerability. |
| A vulnerability was found in Casdoor up to 1.335.0. It has been classified as problematic. Affected is an unknown function of the file /conf/app.conf of the component Configuration File Handler. The manipulation leads to files or directories accessible. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-266838 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
| Elevation of Privileges in the cleaning feature of Gen Digital CCleaner version 6.33.11465 on Windows allows a local user to gain SYSTEM privileges via exploiting insecure file delete operations. Reported in CCleaner v. 6.33.11465. This issue affects CCleaner: before < 6.36.11508. |
| The GLPI Inventory Plugin handles various types of tasks for GLPI agents, including network discovery and inventory (SNMP), software deployment, VMWare ESX host remote inventory, and data collection (files, Windows registry, WMI). Versions prior to 1.5.0 have an improper access control vulnerability. Version 1.5.0 fixes the vulnerability. |
| A security flaw has been discovered in Shenzhen Sixun Software Sixun Shanghui Group Business Management System 4.10.24.3. Affected by this issue is some unknown functionality of the file /ExportFiles/. The manipulation results in files or directories accessible. The attack may be launched remotely. This attack is characterized by high complexity. The exploitation is known to be difficult. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way. |
| NVIDIA Installer for Windows contains a vulnerability where an attacker may be able to escalate privileges. A successful exploit of this vulnerability may lead to escalation of privileges, denial of service, code execution, information disclosure and data tampering. |
| A security vulnerability has been detected in code-projects Simple Food Ordering System up to 1.0. Affected by this vulnerability is an unknown functionality of the file /food/sql/food.sql of the component Database Backup Handler. The manipulation leads to files or directories accessible. It is possible to initiate the attack remotely. The exploit has been disclosed publicly and may be used. It is recommended to change the configuration settings. |