| A web application for configuring the controller is accessible at a specific path. It contains an endpoint that allows a high privileged remote attacker to read files from the system’s file structure. |
| The privileged user could log in without sufficient credentials after enabling an application protocol. This security issue has been fixed in the latest script patch latest version of of Eaton BLSS (7.3.0.SCP004). |
| KuWFi CPF908-CP5 WEB5.0_LCD_20210125 devices have multiple unauthenticated access control vulnerabilities within goform/goform_set_cmd_process and goform/goform_get_cmd_process. These allow an unauthenticated attacker to retrieve sensitive information (including the device admin username and password), modify critical device settings, and send arbitrary SMS messages. |
| An unauthenticated remote attacker can gain full access on the affected devices as they are shipped without a password by default and setting one is not enforced. |
| A unauthenticated adjacent attacker could potentially disrupt operations by switching between multiple configuration presets via CAN. |
| An unauthenticated adjacent attacker could potentially disrupt operations by switching between multiple configuration presets via Modbus (RS485). |
| An unauthenticated remote attacker could potentially disrupt operations by switching between multiple configuration presets via HTTP. |
| Authentication Bypass
vulnerability in Hitachi Ops Center Analyzer on Linux, 64 bit (Hitachi Ops Center Analyzer detail view component), Hitachi Infrastructure Analytics Advisor on Linux, 64 bit (Hitachi Data Center Analytics
component
).This issue affects Hitachi Ops Center Analyzer: from 10.0.0-00 before 11.0.3-00; Hitachi Infrastructure Analytics Advisor: from 2.1.0-00 through 4.4.0-00. |
| Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 all versions, G-50-W all versions, G-50A all versions, GB-50 all versions, GB-50A all versions, GB-24A all versions, G-150AD all versions, AG-150A-A all versions, AG-150A-J all versions, GB-50AD all versions, GB-50ADA-A all versions, GB-50ADA-J all versions, EB-50GU-A all versions, EB-50GU-J all versions, AE-200J all versions, AE-200A all versions, AE-200E all versions, AE-50J all versions, AE-50A all versions, AE-50E all versions, EW-50J all versions, EW-50A all versions, EW-50E all versions, TE-200A all versions, TE-50A all versions, TW-50A all versions, and CMS-RMD-J all versions allows a remote unauthenticated attacker to bypass authentication and then control the air conditioning systems illegally, or disclose information in them by exploiting this vulnerability. In addition, the attacker may tamper with firmware for them using the disclosed information. |
| Synaccess netBooter NP-02x/NP-08x 6.8 contains an authentication bypass vulnerability in the webNewAcct.cgi script that allows unauthenticated attackers to create admin user accounts. Attackers can exploit the missing control check by sending crafted POST requests to create administrative accounts and gain unauthorized control over power supply management. |
| FLIR Brickstream 3D+ 2.1.742.1842 contains an unauthenticated vulnerability that allows remote attackers to access live video streams without credentials. Attackers can retrieve video stream images by directly accessing multiple image endpoints like middleImage.jpg, rightimage.jpg, and leftimage.jpg. |
| FLIR Brickstream 3D+ 2.1.742.1842 contains an unauthenticated vulnerability in the ExportConfig REST API that allows attackers to download sensitive configuration files. Attackers can exploit the getConfigExportFile.cgi endpoint to retrieve system configurations, potentially enabling authentication bypass and privilege escalation. |
| An issue in Casa Systems NTC-221 version 2.0.99.0 and before allows a remote attacker to execute arbitrary code via a crafted payload to the /www/cgi-bin/nas.cgi component. |
| FLIR thermal traffic cameras contain an unauthenticated device manipulation vulnerability in their WebSocket implementation that allows attackers to bypass authentication and authorization controls. Attackers can directly modify device configurations, access system information, and potentially initiate denial of service by sending crafted WebSocket messages without authentication. |
| The iSTAR door controllers running firmware prior to version 6.6.B, does not support authenticated
communications with ICU, which may allow an attacker to gain unauthorized access |
| FLIR thermal traffic cameras contain an unauthenticated vulnerability that allows remote attackers to access live video streams without credentials. Attackers can directly retrieve video streams by accessing specific endpoints like /live.mjpeg, /snapshot.jpg, and RTSP streaming URLs without authentication. |
| An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS. |
| An unauthenticated remote attacker may use the devices traffic capture without authentication to grab plaintext administrative credentials. |
| A vulnerability has been identified in Perfect Harmony GH180 (All versions >= V8.0 < V8.3.3 with NXGPro+ controller manufactured between April 2020 to April 2025). The maintenance connection of affected devices fails to protect access to the device's control unit configuration. This could allow an attacker with physical access to the maintenance connection's door port to perform arbitrary configuration changes. |
| A flaw has been found in Magnetism Studios Endurance up to 3.3.0 on macOS. This affects the function loadModuleNamed:WithReply of the file /Applications/Endurance.app/Contents/Library/LaunchServices/com.MagnetismStudios.endurance.helper of the component NSXPC Interface. Executing manipulation can lead to missing authentication. The attack needs to be launched locally. The exploit has been published and may be used. |