| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A remote unauthenticated network based attacker with access to Junos Space may execute arbitrary code on Junos Space or gain access to devices managed by Junos Space using cross site request forgery (CSRF), default authentication credentials, information leak and command injection attack vectors. All versions of Juniper Networks Junos Space prior to 15.1R3 are affected. |
| ZyXEL PK5001Z devices have zyad5001 as the su password, which makes it easier for remote attackers to obtain root access if a non-root account password is known (or a non-root default account exists within an ISP's deployment of these devices). |
| Information Disclosure can occur in encryptionProfiles.jsd in Hitek Software's Automize because of the Read attribute being set for Users. This allows an attacker to recover encrypted passwords for GPG Encryption profiles. Verified in all 10.x versions up to and including 10.25, and all 11.x versions up to and including 11.14. |
| Information Disclosure can occur in Hitek Software's Automize 10.x and 11.x passManager.jsd. Users have the Read attribute, which allows an attacker to recover the encrypted password to access the Password Manager. |
| The User::randomPassword function in MediaWiki before 1.23.12, 1.24.x before 1.24.5, 1.25.x before 1.25.4, and 1.26.x before 1.26.1 generates passwords smaller than $wgMinimalPasswordLength, which makes it easier for remote attackers to obtain access via a brute-force attack. |
| ZTE ADSL ZXV10 W300 modems W300V2.1.0f_ER7_PE_O57 and W300V2.1.0h_ER7_PE_O57 allow user accounts to have multiple valid username and password pairs, which allows remote authenticated users to login to a target account via any of its username and password pairs. |
| GE Healthcare Centricity DMS 4.2, 4.1, and 4.0 has a password of Muse!Admin for the Museadmin user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value. |
| ZOLL Defibrillator / Monitor M Series, E Series, and R Series have a default password for System Configuration mode, which allows physically proximate attackers to modify device configuration and cause a denial of service (adverse human health effects). |
| GE Healthcare Infinia II has a default password of (1) infinia for the infinia user, (2) #bigguy1 for the acqservice user, (3) dont4get2 for the Administrator user, (4) #bigguy1 for the emergency user, and (5) 2Bfamous for the InfiniaAdmin user, which has unspecified impact and attack vectors. |
| GE Healthcare Discovery 530C has a password of #bigguy1 for the (1) acqservice user and (2) wsservice user of the Xeleris System, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value. |
| Arris DG860A, TG862A, and TG862G devices with firmware TS0703128_100611 through TS0705125D_031115 have predictable technician passwords, which makes it easier for remote attackers to obtain access via the web management interface, related to a "password of the day" issue. |
| Luci in Red Hat Conga stores the user's username and password in a Base64 encoded string in the __ac session cookie, which allows attackers to gain privileges by accessing this cookie. NOTE: this issue has been SPLIT due to different vulnerability types. Use CVE-2013-7347 for the incorrect enforcement of a user timeout. |
| The Data Growth Solution for JD Edwards EnterpriseOne in IBM InfoSphere Optim 3.0 through 9.1 has hardcoded database credentials, which allows remote authenticated users to obtain sensitive information by reading an unspecified field in an XML document. |
| GE Healthcare Discovery XR656 and XR656 G2 has a password of (1) 2getin for the insite user, (2) 4$xray for the xruser user, and (3) #superxr for the root user, which has unspecified impact and attack vectors. NOTE: it is not clear whether these passwords are default, hardcoded, or dependent on another system or product that requires a fixed value. |
| GE Healthcare Precision THUNIS-800+ has a default password of (1) 1973 for the factory default System Utilities menu, (2) TH8740 for installation using TH8740_122_Setup.exe, (3) hrml for "Setup and Activation" using DSASetup, and (4) an empty string for Shutter Configuration, which has unspecified impact and attack vectors. NOTE: since these passwords appear to be used to access functionality during installation, this issue might not cross privilege boundaries and might not be a vulnerability. |
| Ceragon FibeAir IP-10 bridges have a default password for the root account, which makes it easier for remote attackers to obtain access via a (1) HTTP, (2) SSH, (3) TELNET, or (4) CLI session. |
| The web interface on SerVision HVG Video Gateway devices with firmware before 2.2.26a100 has a hardcoded administrative password, which makes it easier for remote attackers to obtain access via an HTTP session. |
| Pearson ProctorCache before 2015.1.17 uses the same hardcoded password across different customers' installations, which allows remote attackers to modify test metadata or cause a denial of service (test disruption) by leveraging knowledge of this password. |
| Inductive Automation Ignition 7.7.2 uses MD5 password hashes, which makes it easier for context-dependent attackers to obtain access via a brute-force attack. |
| Fortinet FortiAuthenticator 3.0.0 has a password of (1) slony for the slony PostgreSQL user and (2) www-data for the www-data PostgreSQL user, which makes it easier for remote attackers to obtain access via unspecified vectors. |