| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Microsoft Skype 7.16.0.102 contains a vulnerability that could allow an unauthenticated, remote attacker to execute arbitrary code on the targeted system. This vulnerability exists due to the way .dll files are loaded by Skype. It allows an attacker to load a .dll of the attacker's choosing that could execute arbitrary code without the user's knowledge.The specific flaw exists within the handling of DLL (api-ms-win-core-winrt-string-l1-1-0.dll) loading by the Skype.exe process. |
| An Uncontrolled Search Path Element issue was discovered in Solar Controls WATTConfig M Software Version 2.5.10.1 and prior. An uncontrolled search path element has been identified, which could allow an attacker to execute arbitrary code on a target system using a malicious DLL file. |
| Untrusted search path vulnerability in NFC Port Software remover Ver.1.3.0.1 and earlier allows an attacker to gain privileges via a Trojan horse DLL in an unspecified directory. |
| Untrusted search path vulnerability in NFC Port Software Version 5.5.0.6 and earlier (for RC-S310, RC-S320, RC-S330, RC-S370, RC-S380, RC-S380/S), NFC Port Software Version 5.3.6.7 and earlier (for RC-S320, RC-S310/J1C, RC-S310/ED4C), PC/SC Activator for Type B Ver.1.2.1.0 and earlier, SFCard Viewer 2 Ver.2.5.0.0 and earlier, NFC Net Installer Ver.1.1.0.0 and earlier allows an attacker to gain privileges via a Trojan horse DLL in an unspecified directory. |
| Code injection vulnerability in Avira Total Security Suite 15.0 (and earlier), Optimization Suite 15.0 (and earlier), Internet Security Suite 15.0 (and earlier), and Free Security Suite 15.0 (and earlier) allows a local attacker to bypass a self-protection mechanism, inject arbitrary code, and take full control of any Avira process via a "DoubleAgent" attack. One perspective on this issue is that (1) these products do not use the Protected Processes feature, and therefore an attacker can enter an arbitrary Application Verifier Provider DLL under Image File Execution Options in the registry; (2) the self-protection mechanism is intended to block all local processes (regardless of privileges) from modifying Image File Execution Options for these products; and (3) this mechanism can be bypassed by an attacker who temporarily renames Image File Execution Options during the attack. |
| In Adam Kropelin adk0212 APC UPS Daemon through 3.14.14, the default installation of APCUPSD allows a local authenticated, but unprivileged, user to run arbitrary code with elevated privileges by replacing the service executable apcupsd.exe with a malicious executable that will run with SYSTEM privileges at startup. This occurs because of "RW NT AUTHORITY\Authenticated Users" permissions for %SYSTEMDRIVE%\apcupsd\bin\apcupsd.exe. |
| mcmnm in BMC Patrol allows local users to gain privileges via a crafted libmcmclnx.so file in the current working directory, because it is setuid root and the RPATH variable begins with the .: substring. |
| Untrusted search path vulnerability in LhaForge Ver.1.6.5 and earlier allows an attacker to gain privileges via a Trojan horse DLL in an unspecified directory. |
| An Uncontrolled Search Path Element issue was discovered in SIMPlight SCADA Software version 4.3.0.27 and prior. The uncontrolled search path element vulnerability has been identified, which may allow an attacker to place a malicious DLL file within the search path resulting in execution of arbitrary code. |
| In EMC VNX2 versions prior to OE for File 8.1.9.211 and VNX1 versions prior to OE for File 7.1.80.8, a local authenticated user can load a maliciously crafted file in the search path which may potentially allow the attacker to execute arbitrary code on the targeted VNX Control Station system, aka an uncontrolled search path vulnerability. |
| A DLL Hijacking vulnerability in the programming software in Schneider Electric's SoMachine HVAC v2.1.0 allows a remote attacker to execute arbitrary code on the targeted system. The vulnerability exists due to the improper loading of a DLL. |
| An Uncontrolled Search Path Element issue was discovered in Solar Controls Heating Control Downloader (HCDownloader) Version 1.0.1.15 and prior. An uncontrolled search path element has been identified, which could allow an attacker to execute arbitrary code on a target system using a malicious DLL file. |
| There exists a path traversal vulnerability in the Android Google Search app. This is caused by the incorrect usage of uri.getLastPathSegment. A symbolic encoded string can bypass the path logic to get access to unintended directories. An attacker can manipulate paths that could lead to code execution on the device. We recommend upgrading beyond version 13.41 |
| Missing DLLs, if replaced by an insider, could allow an attacker to achieve local privilege escalation on the DeltaV Distributed Control System Controllers and Workstations (All versions) when some DeltaV services are started. |
| AVEVA Software Platform Common Services (PCS) Portal versions 4.5.2, 4.5.1, 4.5.0, and 4.4.6 are vulnerable to DLL hijacking through an uncontrolled search path element, which may allow an attacker control to one or more locations in the search path. |
| DWG TrueViewTM 2023 version has a DLL Search Order Hijacking vulnerability. Successful exploitation by a malicious attacker could result in remote code execution on the target system. |
| Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft Windows systems. |
| Delta Electronics DIAEnergie (all versions prior to 1.8.02.004) are vulnerable to a DLL hijacking condition. When combined with the Incorrect Default Permissions vulnerability of 4.2.2 above, this makes it possible for an attacker to escalate privileges |
| The application searches for a library dll that is not found. If an attacker can place a dll with this name, then the attacker can leverage it to execute arbitrary code on the targeted Softing Secure Integration Server V1.22. |
| AutomationDirect DirectLOGIC has a DLL vulnerability in the install directory that may allow an attacker to execute code during the installation process. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73; EA9-T6CL-R versions prior to 6.73; EA9-T7CL versions prior to 6.73; EA9-T7CL-R versions prior to 6.73; EA9-T8CL versions prior to 6.73; EA9-T10CL versions prior to 6.73; EA9-T10WCL versions prior to 6.73; EA9-T12CL versions prior to 6.73; EA9-T15CL versions prior to 6.73; EA9-RHMI versions prior to 6.73; EA9-PGMSW versions prior to 6.73; |